57

LED Display:

System Ready
Data carrier Present
Data carrier
Operating
58
Assembling the
BIS C-600 processor
and configuring the
read/write head or
BIS C-650 adapter
58
english
LED Display
The BIS C-600 Processor uses three LED's on the front panel to indicate the most important
operating conditions.
Condition
LED
Meaning
System
on (green)
Supply voltage OK; no hardware error
Ready
off
Supply voltage or hardware not OK or
read/write head cable break or not connected.
Data carrier on (yellow)
Data carrier ready to read or write. (If a read/write error occurs
during
Present
a read/write operation, System Ready LED goes out,
if the protocol variant "without error number" is used!)
flashes
Read/write head cable break or not connected.
If both read/write heads were selected using 'HT', one head may
not be connected.
If both read/write heads are selected, the cable break message
only comes if there is no data carrier in front of the connected,
functional head.
off
No data carrier in active zone of read/write head
Data carrier on (yellow)
Command being processed
Operating
off
No command in process
If all three LED's flash on and off in synch, the processor needs to be returned to the factory for repair.
BIS C-600
Processor / Head Assembly
The processor is attached at the 4 side through-holes.
Depending on the
processor version either
a read/write head or the
adapter for remote read/
write head is fitted. Both
the read/write head and
the adapter can be
rotated by the user by +
or - 90° to the desired
orientation (see illustra-
tion). Be sure that the
device is turned off.
Remove both screws
(indicated by arrows in
the illustration). Carefully
pull the head or adapter
out towards the side
(direction of arrow, right
illustration). Caution:
Internal cable connec-
tion! Attach it in the
desired position and
tighten down with the
screws.