Error Numbers

54
Error Numbers
(continued)
54
english
Error Numbers
The BIS C-600 always outputs an error number. The meaning of these error numbers is
indicated in the following table.
No. Error Description
Effect
1
No data carrier present
Telegram aborted,
processor goes into ground state.
2
Read error
Read telegram aborted,
processor goes into ground state.
3
Read aborted, since the
Processor goes into ground state.
data carrier was
removed.
4
Write error
Write telegram aborted,
processor goes into ground
state.
5
Writing aborted,since the
Processor goes into ground
data carrier was
state.
removed.
6
Interface error
Processor goes into ground state.
(parity or stop bit error)
7
Telegram format error
Processor goes into ground state. Possible format errors:
- Command is not 'L'/'P'/'C'/'R'/'W'/'H'/'B'/'Q'/'S'/'Z'.
- Start address or number of bytes exceed permissible range
*) Note: If a CRC data check is used, error message "E" could result if error 4 or 5 was not
cleared.
Error Numbers
No. Error Description
8
BCC error, the trans-
mitted BCC is wrong.
9
Cable break from
read/write head or
cable not connected,
Codetag Present
LED flashes.
A
New command not
possible, since a read
command is already in
process.
B
New command not
possible, since a write
command is already in
process.
C
New command not
possible, since a head
select is already in process.
E
CRC error: the CRC on the
data carrier is wrong. *)
I
EEPROM error
*) Note: If a CRC data check is used, error message "E" could result if in the preceding command
error 4, 5 or B was reported.
CAUTION: An aborted write
could cause new data to be
written to the data carrier
which may be incomplete! *)
Effect
Telegram is aborted,
processor goes into ground state.
Telegram is aborted,
processor goes into ground state.
If both read/write heads were selected using 'HT', one
head may not be connected. If both read/write heads are
selected, the cable break message only comes if there is
no data carrier in front of the connected, functional head.
After error message the read command is stopped,
internally, but not acknowledged.
Processor goes into ground state.
After error message the write command is stopped,
internally, but not acknowledged.
Processor goes into ground state.
After the error message, no positive acknowledge is given,
even thought the head select was successful.
Processor goes into ground state.
Telegram aborted,
processor goes into ground state.
Telegram aborted,
processor goes into ground state.
53
english