Herunterladen Inhalt Inhalt Diese Seite drucken

Display Elements; Labeling - Balluff BNI EIP-508-105-Z067 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für BNI EIP-508-105-Z067:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

00-19-31-XX-XX-XX
BNI EIP-508-105-Z067
LK1
Network interface
IP
P
S
SN
GW
3
2
1
0
4
Product description (continued)
IN
POWER
4.3

Display elements

BNIXXXX
BNI XXX-XXX-XXX-XXX
US
UA
MOD NET
100
LK1
100
LK2
0
00
01
08
1
Fig. 4-3:
Display elements
Port/Pin LEDs
02
03
10
LED number
2
Even
Odd
04
05
12
Tab. 4-1:
Port/Pin LEDs
3
Port/Pin LEDs Standard Port
06
07
14
Signal
Meaning
Off
State of input or output pins is 0
Yellow, static
State of input or output pins is 1
Both LEDs
Short circuit of sensor supply between
flashing red
pin 1 and pin 3
Red, static
Short circuit at output on pin 2/4 against
pin 3
Red, static
No high signal at diagnostic input
Red, static
24 V input signal on configured output
(actuator warning)
Tab. 4-2:
LEDs Standard Port
Port/Pin LEDs IO-Link Port
Signal
Meaning
Green, static
IO-Link connection active
Flashing
No IO-Link connection or incorrect
green
IO-Link device
Green, fast
IO-Link: Preoperate during data storage
flashing
Red, fast
Validation failed / incorrect configuration
flashing
of the IO-Link data length
Red, fast
Data storage failed / incorrect device for
flashing
data storage
Red, static
IO-Link: Short circuit of pin 4 against
pin 3
Tab. 4-3:
LEDs IO-Link Port
8
english
MAC-ID
LK2
OUT
Status LEDs
4
Port/Pin LEDs:
09
Status of IO-Link and
5
I/O-Ports
11
Assignment
6
Pin 4
Pin 2
13
7
15
Status LEDs
LED
Signal
Meaning
US
Green, static
Input voltage OK
Red flashing
Input voltage low (< 18 V)
UA
Green, static
Output voltage OK
Red flashing
Output voltage low (< 18 V)
Red, static
No output voltage present
(< 11 V)
MOD Flashing
Incorrect or no module
green
configuration
Green, static
Module working
Red flashing
Fixed bus cycle not possible
Red/Green
Starting sequence
flashing
NET
Off
Module has no IP address
LK1
Flashing
Module has an IP address, but no
green
connection established
Green, static
Connection is established
Red flashing
Connection timeout
IP
Red/Green
Starting sequence
P
S
SN
flashing
GW
100
Off
Transmission rate: 10 Mbit/s
3
2
Yellow, static
Transmission rate: 100 Mbit/s
LK1/2 Flashing
Data transfer
green
IN
Tab. 4-4:
Status LEDs
POWER
4.4

Labeling

BNIXXXX
BNI XXX-XXX-XXX-XXX
US
UA
MOD NET
Order code
0
Fig. 4-4:
Labeling (example)
00
01
1
02
03
2
04
05
3
MAC-ID
00-19-31-XX-XX-XX
LK2
1
0
OUT
100
LK1
100
LK2
Type
4
08
09
5
10
11
6
12
13
7

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis