Inspection - BWT AQA perla XL Einbau- Und Bedienungsanleitung

Duplex-weichwasseranlage
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

EN
9.3

Inspection

(Carried out by the operator in accordance with
EN 806-5)
Inspection activities
Check/refill regenerative
Check brine containers for
soiling
Check for leaks, visual
inspection
Functional test/control unit
display
Test regenerative consump-
tion depending on the treated
water
Check the setting of the
regeneration waste water
system
Check the counting function
of the water meter
Test the regeneration process
Clean the brine container
and the internal surfaces that
come into contact with water
84
Interval
Note for products
WITHOUT active BWT
DES registration
According
to use
Every 2
months
Every 2
months
Every 2
months
Every 2
months
Every 2
months
Every 2
months
Every 2
months
Every 6
months
WITH active BWT DES
Required
Required
Required
Required
Required
Required
Required
Required
Required
Note for products
registration
Required
Required
Required
Not required
Not required
Required
Not required
Not required
Required