Herunterladen Inhalt Inhalt Diese Seite drucken

51 8.6 Check The Water Hardness - BWT AQA perla XL Einbau- Und Bedienungsanleitung

Duplex-weichwasseranlage
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

EN
10:10:37
245 l
Hardness
IN:
22 °d
OUT:
0
Hardness
20
72
10
121 l
8.6
Check the water hardness
The hardness of the drinking water and the set
hardness of the outlet water must be checked during
start-up and once a month thereafter, and corrected
if necessary.
Information about the outlet water hardness
The Trinkwasserverordnung (German drinking
water ordinance) stipulates a sodium limit of
200 mg/l. The limit has been set this low so that
people on a low sodium diet can still consume
drinking water and use it for cooking.
Reducing the hardness of drinking water by
1°dH increases the sodium content by 8.2 mg/l.
(Drinking water hardness – Outletwater hardness)
x 8.2 mg/l = increase in sodium content.
Test the water hardness
Fully open the tap at the nearest cold water tap point
upstream and downstream of the water softener and
run the water for 1 minute. Use AQUATEST to test
the hardness of the water and make a note of it.
Correct the water hardness
Press the water droplet
Press drinking water hardness

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis