Troubleshooting:

Cleaning performance with the cleaning attachment is insufficient:
The rotation nozzle is not turning
Scaly deposits on the rotor
Blocked by particles of dirt
Turn multiple time manually (make sure the high pressure cleaner is depressurized before doing so)
Disassemble and clean
In case of excessive and sudden water pressure, the cleaning head can freeze. In this case, press the high pressure
cut off trigger multiple times.
Is the high pressure cleaner producing sufficient pressure?
Is there a sufficient supply of water to the high pressure cleaner? (Inlet line must be ¾")
The rotating nozzle may be worn and need replacing.
No water is being discharged from the suction unit:
Air pocket in the pump
Is the power lead for the immersion pump plugged in at the suction basket?
The immersion pump is standing in mud and can't extract water
Discharge hose kinked.
No vacuum or insufficient vacuum:
Vacuum flow interrupted due to excessive solid build up in filter basket
Machine switched off by thermocouple (caused by vacuum flow interruption / blocked, kinked, or sagging suction
hose / excessive water temperature)
Is the top section with motor positioned precisely on the lower barrel?
Check the sealing ring on the filter basket between the barrel parts for signs of damage and soiling
Check the suction hose coupling
Only one suction motor switched on
Rollers on the cleaning attachment not turning:
Casters stuck or dirty. Move attachment back and forth on a durable, insensitive base by applying a slight pressure.
Replace the casters if they cannot be freed.
Water escaping from the attachment:
Clean sealing brushes to remove clogging, or replace brushes.
Insufficient vacuum build up
Incorrect height setting of sealing brushes
Vacuum flow interruption triggered (clean filter basket)
Unable to actuate cleaning attachment trigger:
Release the lock
Vacuum switching off:
Machine switched off by thermocouple (caused by vacuum flow interruption
blocked, kinked, or sagging suction hose / excessive water temperature)
Check power supply: the circuit breaker may have triggered. Use only 2.5mm² diameter
extension lead. Total length must not exceed 30 metes. Completely unwind extension reels.
Bellow air filter below suction unit wet and / or soiled
Check if the pump plug is plugged into the suction unit (otherwise the water level will rise and the vacuum flow
interrupter will trigger).
Switch motors on individually.
Attach all machines to different power supplies.
Check the 230V power supply.
Set both main switches to "0" position. Remove the cause of the malfunction and switch the machine back on after
waiting for approx. 5 min.
Translation of the original instruction
66