Herunterladen Inhalt Inhalt Diese Seite drucken

Power Options; Technical Data - Lansinoh 2in1 Elektrische Doppelmilchpumpe Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Using the Lansinoh
2in1 Electric Breast Pump
®
4 . When a pumping session is finished, turn the pump off with the On/Off Button . After turning
the pump off, the display will remain on for a few seconds . Make sure there is no suction on the
nipple(s) before removing the breast cushions from the breast . If necessary, break the suction
by inserting a finger between the breast cushion and the breast . Once the suction is broken, the
breast cushion can be removed safely .
Please note: LCD display back light will automatically switch off if no control buttons are pressed
for 20 seconds in order to save power . If the pump unit is left switched on and unattended for
more than 60 minutes, the control system will automatically switch the power off . You have to
press and hold the On/Off Button in order to switch the unit back on again .
NOTE: If the suction on your breast reaches uncomfortable levels, reduce the suction level by
pushing the
Suction Level Decrease Control Button, or disconnect the tubing connector from
its tubing input on the electric pump base .

8. POWER OPTIONS

The pump may be operated under any of the following power supply modes:
Do not mix old and new batteries . Do not mix alkaline and standard (carbon-zinc) batteries .
If batteries are in the pump, but AC adapter is in use, the pump will use the adapter to power the
pump, not the batteries . For the most economical use, we recommend using your pump with the AC
adapter provided . Your AC adaptor is a universal AC plug adaptor type and can be used with 100 V
to 240V systems with 50Hz and 60Hz mains .
9. BREASTMILK STORAGE GUIDELINES
Breastmilk Storage and Thawing Guidelines For Healthy Term Babies
Check with your healthcare professional, midwife or health visitor for specific storage instructions .
When you are freezing your breastmilk, do not fill containers more than ¾ full to allow for expansion
from freezing . Date containers with the date you expressed your milk for future reference . Use the
oldest breastmilk first .
After two minutes, the Let-Down (Stimulation) Phase
will automatically change and put you into Pumping
Style 2 in the Expression Phase . The let-down icon will
disappear from the LCD display and the expression
icon
will appear
.
If you prefer to bypass the pre-set two minute Let
Down (Stimulation) Phase or your milk lets down
sooner than two minutes press the Let-Down Button
to move to the Expression Phase, where you can
separately select the pumping style and suction levels .
Note – the Pumping Style Indicator
will appear in
the display to indicate that you are in the Expression
Phase and the let-down indicator will disappear.
The pumping styles can be changed using the
pumping style button . Pressing this button will switch
between the three styles
.
Note – if at any time the suction on your breast
reaches uncomfortable levels, reduce the suction
level by pressing the button on the left side of the
LCD screen. You can control suction levels in both
phases by pressing the + and - buttons.
AC Adapter (included)
Connect the AC adapter to the power
connector socket located on the right
side of the pump .
Plug the AC adapter into an available
electrical outlet . Electrical safety can
only be achieved when the breast pump
is connected to the AC Power Adapter
supplied with the product . (See
"Technical Data" section)
6 AA Alkaline Batteries (not included)
Make sure the batteries are inserted
correctly according to the polarity (+)
and (-) as indicated . Close the
compartment by gently pressing the
cover until it snaps into place .
Remove batteries if pump is not in use
for a long period of time . Dispose of
batteries according to regulations for
environmental protection and recycling .
Replace all batteries at the same time .
Please note that the pump is not
designed to be used with rechargeable
batteries .
Milk Storage Guidelines, Full term infant
WHERE
TEMPERATURE
At Room
60-80° (16-26°C)
Temp .
Insulated
39-59° (4-15°C)
Cooler Bag
In a
<39°F (<4°C)
Refrigerator
Freezer
0°F (-18°C)
Deep Freezer
-4°F (-20°C)
Source: La Leche League International 2017
Note: DO NOT store breastmilk in freezer door. The door tends to be the warmest part of the
freezer.
Thawing
Thaw frozen milk in the refrigerator or place the containers under cool running water, gradually
warming the water until the milk is thawed . Thawed milk can be kept in a refrigerator for up to 24
hours .
NOTE: DO NOT refreeze milk once it is thawed.
Gently shake thawed milk before feeding to baby to mix the layers that have separated . Breastmilk is
not homogenized and the "cream" will rise to the top of the bottle . Breastmilk can vary in colour and
consistency depending upon the time of the day that the milk was expressed, what you have eaten,
and the age of the baby at the time of pumping .
NOTE: DO NOT MICROWAVE HUMAN MILK! Microwaving alters the composition of the milk.
Microwaving also may create "hot spots" in the milk that could burn
NOTE: DO NOT thaw breastmilk in hot or boiling water.

10. TECHNICAL DATA

The expected service life of the pump is 500 hours .
1. Power Supply
Battery operation: 6 AA size alkaline batteries (not included), all connected in series . Do not use
rechargeable batteries
Operating time: Minimum 30 minutes . Maximum 2 hours . Results are dependent on battery freshness
and pump settings .
AC Adaptor operation: 100-240VAC wall plug type AC adaptor, galvanically isolated with 9V output
voltage
Pump power dissipation: 10 Watts maximum
Voltage regulation: Linear voltage regulator with low dropout voltage and short circuit protection
2. Control System
Control unit: Microcontroller with integral program memory
Program memory: 32K flash ROM, 2K RAM memory
HMI: LCD display with LED backlight, soft keypad
Single / double control: Single or double breast pumping possible
Selectable pumping styles: 3 pumping styles are selectable and controlled from keypad
Adjustable suction level: 8 suction levels are selectable and controlled from keypad
Suction vacuum level (Expression/Double pumping): Minimum 90mmHg, Maximum 280mmHg
SYMBOLS
Follow instructions for use
Identifies the manufacturer
Indicates the date of manufacture
Type BF applied part
Class II equipment
Keep the device dry
TIME
ACTION
Contents should be covered
4 hours
and kept as cool as possible;
(ideal) up to
covering the container with
6 hours (ac-
a damp towel may keep milk
ceptable)
cooler
Keep ice packs in constant
24 hours
contact with milk containers;
limit opening cooler bag
4 days (ideal)
Store milk in the back of the
up to 5 days
main body of the refrigerator
(acceptable)
3 months
(ideal) up to
6 months (ac-
Store milk away from sides and
ceptable)
toward the back of the freezer
where temperature is most
6 months
constant
(ideal) up to
12 months
(acceptable)
MEANING OF THE SYMBOLS
6

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

53458

Inhaltsverzeichnis