DISPLAYING
Err3
The display shows
Err4
The display shows
Err5
The display shows
Err7
The display shows
Err8
The display shows
Err9
The display shows
Er10
The display shows
Er13
The display shows
Er14
The display shows
DESCRIPTION
When a start command is given the gate
won't open.
It means that the photocell test failed.
When a Start command is given and the
gate does not open (or does a partial
opening).
It means that the limit switche has not been
released or that both limit switches are
active.
When a start command is given the gate
won't open.
It means that the test of the safety edges
failed.
Encoder error
When executing a self-learning function the
control is refused.
It means that the setting of the control
unit is not compatible with the requested
function.
It means that programming was locked by
means of the programming lock key CL1+
(code 161213).
When a start command is given the gate
won't open.
This means that the ADI module function
test failed.
The self-diagnosis circuit has detected
a malfunction that prevents the safe
operation of the automation
The self-diagnosis circuit has detected an
error in the configuration parameter table
SOLUTION
1. Be sure that no obstacle interrupted the photocell
beam when the Start command was given.
2. Be sure that photocells, as enabled by their relevant
menus, have been installed actually.
3. If you have photocells 2, be sure that
CF.Ch
item is on
4. Be sure that photocells are powered and working:
interrupt the ray and check that the photocell segment
on the display changes position.
5. Ensure the photocells are connected correctly, as
shown in the chapter 5.5
Make sure that the limit switches are correctly connected
and the gate, opening, let the limit switch open.
If the limit switches are not used set the parameter
FC.En
no
=
1. Make sure that the menu relative to the test of the
facets for cables (
2. Make sure that the safety edges enabled by menu are
actually installed.
3. Check the safety edges are correctly connected as
indicated in chapter 5.6.
Check the connection of the encoder
1. Check the Start inputs are enabled in standard mode
Strt
(
menu set on
2. Check the ADI interface is disabled
i.Adi
(
menu set to
To change the settings it is necessary to insert in the
connector of the ADI interface the same key used to
activate the programming lock, and unlock the device.
1. Check the ADI module is correctly inserted
2. Check the ADI module is not damaged and working
properly
Contact the V2 technical assistance service to send the
control unit for repair
Enter the configuration menu, carefully check all the
parameters and correct any errors. If the error persists,
contact the V2 technical assistance service to send the
control unit for repair
- 60 -
Fot2
menu
.
Co.tE
) is configured correctly.
StAn
).
no
).