PARAMETER
VALUE
Pot1
30 - 100
Pot2
30 - 100
SPUn
Si
no
rAM
0 - 6
rA.AP
no
1 - 50
rA.Ch
no
1 - 50
t.CvE
0.0" - 5.0"
tE.M
Si
no
DESCRIPTION
Motor M1 power
The displayed value is the percentage of max. motor power.
WARNING: In case an hydraulic motor is used, set value 100
Motor M2 power
The displayed value is the percentage of max. motor power.
WARNING: In case an hydraulic motor is used, set value 100
Start off
When the gate is standstill and it begins moving, the initial inertia
must be faced, therefore, if your gate is quite heavy, its doors could
not move.
SPUn
In case the
(pickup) function is activated, for the first 2 seconds
of motion of each door, the control unit will ignore both
Pot2
values and it will give motors the maximum power command
in order to overcome the gate inertia.
Function activated
Function deactivated
Starting ramp
In order not to stress too much the motor, when the motion starts the
power is gradually increased, until reached the set value or 100% if
the take-off is enabled.
Higher is the set value, longer the length of time of the ramp, that is
the time necessary to reach the value of nominal power.
Slow down in opening
Function deactivated
This menu allows regulating the percentage of the ride/drive that is
carried out at reduced speed during the last opening stretch
Slow down in closing
Function deactivated
This menu allows regulating the percentage of the ride/drive that is
carried out at reduced speed during the last closing stretch
Fast closing time after slowing down
If a slowing time other than 0 is set up, it could be likely that the gate
speed is not enough for the lock to fasten during the closing phase.
In case this function is enabled, once the slowing down phase is
finished, the control unit will give a normal speed command (that is to
say, with no slowing down) for the set up time, and then it will open
the gate for a second fraction, to avoid leaving the motor under stress.
m
0
PLEASE NOTE: Set to
locks or if slowing is disabled.
Enabling the test motor
The unit performs an operation test on the motor before starting the
automation.
ATTENTION: disable this function only if it is necessary to perform
emergency manoeuvres.
Function activated
Function deactivated
Pot1
if the gate is not fitted with electro-
- 52 -
AntE SCor
60
60
60
60
Si
Si
and
4
4
25
15
25
15
0.0"
0.0"
Si