EVENT CODE
DESCRIPTION
E001
The microprocessor has been reset
E002
Access to the programming menu of the control unit
E003
Loading the DEFAULT parameters
E004
Self-learning of the working times
E015
Activating STOP
E019
Activating the virtual STOP (control from an ADI device)
E020
TRIAC test error
E031
Photocell test error detected on the FOT1 input
E032
Photocell test error detected on the FOT2 input
E036
FOT1 Photocell activation
E037
FOT2 Photocell activation
E039
Activating the virtual photocell (control from an ADI device)
E041
Limit switch error on opening
E042
Limit switch error on closing
E045
The M1 motor closes before the M2 motor
E046
Command rejected because it was already at the limit switch
E051
Strip test error detected on the COS1 input
E052
Strip test error detected on the COS2 input
E056
Activation of the COS1 safety strip
E057
Activation of the COS2 safety strip
E059
Activation of the virtual safety strip (control from an ADI device)
E066
Intervention of the amperometric protection on opening
E067
Intervention of the amperometric protection on closing
E068
Three obstacles detected on closing
E072
Encoder direction error
E080
Error during the self-learning procedure
E090
Attempt to access the programming menu blocked by CL1+
E100
Error detected on a safety device controlled by the ADI interface
E130
Motor ignition relay failure
E131
Triac sensor test circuit failure
E140
Checksum error or parameter redundancy
E200
Inversion of movement caused by a command
E201
START command from the terminal board
E202
PEDESTRIAN START command from the terminal board
E203
START command from the ADI device
E209
Transmitter channel 1
E210
Transmitter channel 2
E211
Transmitter channel 3
E212
Transmitter channel 4
E240
Closing the gate as the idle time set in
E241
Closing due to the inactivity being delayed
E242
Activating the ENERGY SAVING function
t.inA
parameter has been exceeded
- 48 -
LEVEL
DISPLAY
0
0
0
0
StoP
2,3,4
i.Adi
3
Err2
1
Err3
1
Err3
1
Fot1
2,3,4
Fot2
2,3,4
i.Adi
2,3,4
Err4
1
Err4
1
invE
2
APEr / ChiU
3
Err5
1
Err5
1
CoS1
2,3,4
CoS2
2,3,4
i.Adi
2,3,4
SEnS
2
SEnS
2
SEnS
2
Err7
1
Err8
1
Err9
1
Er10
1
Er13
1
Er13
1
Er14
1
Strt
2
4
4
4
tEL1
4
tEL2
4
tEL3
4
tEL4
4
5
5
5