PARAMETER
VALUE
St.AP
PAUS
ChiU
no
St.Ch
StoP
APEr
St.PA
ChiU
no
PAUS
SPAP
PAUS
ChiU
no
Ch.AU
no
0.5" - 20.0'
Ch.tr
no
0.5" - 20.0'
PA.tr
no
Si
DESCRIPTION
Start command during the opening phase
This menu allows fixing the control unit conduct in case it receives a
Start command during the opening phase
The gate stops and goes to pause
The gate immediately starts closing
The gate go on with the opening phase (command is ignored)
Start command during the closing phase
This menu allows fixing the control unit conduct in case it receives a
Start command during the closing phase
The gate stops and its cycle is considered as finished
The gate opens again
Start command during the pause
This menu allows fixing the control unit conduct in case it receives a
Start command when the gate is open during its pause phase
The gate starts closing
Command is ignored
Ch.AU
The pause time is reset (
Pedestrian Start during the partial opening phase
This menu allows fixing the control unit conduct in case it receives a
Pedestrian Start command during the partial opening phase.
m
WARNING: a Start command in any phase of partial opening
will cause the total opening; the Start Pedestrian command is always
ignored during a total opening.
The gate stops and goes to pause
The gate immediately starts closing
The gate goes on with the opening phase (command is ignored)
Automatic closing
Function deactivated
The gate closes after the setup time
Closing after transit
This function allows having a fast closing as soon as transit through
the gate is completed, therefore, a time shorter than
generally used
Function deactivated. The gate closes after the time set for the
Ch.AU
function
The gate closes after the setup time
Pause after transit
In order to let the gate open for the shortest possible time, it is
possible to stop the gate once the passage before the photocells is
detected.
If the automatic working is enabled, the time of the pause is
Function deactivated
Function activated
)
Ch.AU
- 53 -
AntE SCor
PAUS PAUS
StoP StoP
ChiU
ChiU
PAUS PAUS
no
no
no
no
is