PARAMETER
VALUE
En.SA
no
Si
t.AP1
0.0"-5'00
t.AP2
0.0"-5'00
t.Ch1
0.0"-5'00
t.Ch2
0.0"-5'00
t.APP
0.0" - 2'00
t.ChP
0.0" - 2'00
t.C2P
0.5" - 1'00
no
r.AP
0.0" - 1'00
DESCRIPTION
ENERGY SAVING function
When the function is active and the LOW ENERGY module is installed,
the control unit deactivates the display, the photocells, and all the
devices powered by a terminal box under determined conditions.
NOTE: If the LOW ENERGY module is not installed, the control unit
deactivates only the display.
The control unit activates the ENERGY SAVING mode under the
following conditions:
• 30 seconds after completion of an operational cycle
• 30 seconds after an opening (if automatic closure is not enabled)
• 30 seconds after exiting the programming menu
The control unit exits from the ENERGY SAVING mode in these cases:
• If an operational cycle is activated
• If one of the keys on the control unit are pressed
Function deactivated
Function activated
Leaf 1 opening time
Adjustable time from 0 seconds to 5 minutes
Leaf 2 opening time
Adjustable time from 0 seconds to 5 minutes.
WARNING: if motor M2 is not connected, this time must be set to
zero
Leaf 1 closing time
Adjustable time from 0 seconds to 5 minutes.
NOTE: To avoid that the door does not close completely, we
recommend to setup a longer time than
Leaf 2 closing time
Adjustable time from 0 seconds to 2 minutes
NOTE: To avoid that the door does not close completely, we
recommend to setup a longer time than
Partial opening time (pedestrian access)
When the control unit receives a Start Pedestrian command, it
will open leaf 1 only, for a shorter time.
Max allowed time to be setup is
Partial closing time (pedestrian access)
When the control unit receives a Start Pedestrian command, it will use
this time to close the gate. Max allowed time to be setup is
NOTE: To avoid that the door does not close completely, we
recommend to setup a longer time than
Leaf 2 closing time during pedestrian cycle
During a partial opening cycle (pedestrian access) leaf 2 may move
slightly because of the wind or its own weight; in this case at closing
time leaf 1 could hit leaf 2 and the gate would remain not perfectly
closed. To avoid this, in the last seconds of the cycle a light closing
force is applied to leaf 2 too.
Function deactivated
Opening door delay
During the opening phase, leaf 1 must start moving before leaf 2, to
avoid that both doors may collide.
Leaf 2 opening will be delayed for the setup time.
NOTE: If you set the opening door delay to zero, the control board
does not execute the control of the correct leaves closing order
t.AP1
opening time.
t.AP2
opening time
t.AP1
t.APP
opening time
- 50 -
AntE SCor
no
no
20.0" 22.5"
20.0" 0.0"
21.0" 23.5"
21.0"
0.0"
6.0"
6.0"
7.0"
7.0"
t.Ch1
.
2.0"
no
1.0"
0.0"
MEMO