5.10 - LOW VOLTAGE LIGHT

The control unit has a 12Vdc output that allows connections to a
load up to 3W.
This output can be used to connect a signal light that indicates
that status of the gate, or for a low voltage flashing light.
Connect the low voltage signal light or flashing light wires to
terminals Z5 (+) and Z6 (-).
C
To activate the function, change the settings of parameter
SPiA
Z1 Z2 Z3 Z4 Z5 Z6
m
CAUTION: Pay attention to the polarity of the
connected device if necessary

5.11 - LOCK

An electric lock can be assembled on the gate, to ensure a good
closing of doors. Make use of a 12V lock.
Connect lock cables to terminals Z4 and Z5 of the control unit.
C
To modify the times of action of the lock, check the settings
of the following parameters:
t.SEr
-
lock time
t.ASE
-
advanced lock time
If the electric lock has difficulties in the early stages of release or
engagement, there are functions to facilitate these operations:
1. Backlash time: before starting an opening the motors are
driven into closing to facilitate the release of the lock.
C
To activate this function set the ram hammering time
t.inv
through the
parameter
2. Fast closing time after slowdown: once completed the
slowdown stage, the unit orders closing at normal speed
(without slowdown) to facilitate engagement of the lock.
C
To activate this function, set the fast closing time through
t.CvE
the
parameter
12Vdc - 3W
Z1 Z2 Z3 Z4 Z5 Z6
12V

5.12 - EXTERNAL AERIAL

We suggest to use the external aerial (model: ANS433) in order to
guarantee the maximal range.
Connect the antenna hot pole to terminal L1 of the control unit
and the braiding to terminal L2.

5.13 - POWER SUPPLY

The control unit must be fed by a 230V - 50Hz (120V - 50/60Hz
for 120V model) electric line, protected by a differential
magnetothermal switch complying with the law provisions in
force.
Connect power supply cables to terminals L and N.
230V - 50Hz
- 41 -
L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11
N
L