ELECTRICAL FUSES

The following fuses are located under the hood (10, Fig.
C):
Circuit breakers, which can be reset by pressing the
relevant key:
– Drive system fuse (11, Fig. U)
– Main broom/vacuum fan motor fuse (10, Fig. U)
Lamellar fuses, protected by a transparent plastic
cover (9, Fig. U), which protect the following circuits:
– Fuse F1 (25 A): Main fuse (ignition switch circuit)
– Fuse F2 (25 A): Filter shaker motor
– Fuse F3 (40 A): Manual vacuum system (optional)
– Fuse F4 (10 A): Horn and pivoting light
– Fuse F5 (10 A): Working light (optional)
– Fuse F6 (10 A): Side broom motors
– Fuse F7 (25 A): Spare
– Fuse F8 (10 A): Spare
On the drive system electronic board there is the following
fuse:
– Drive system electronic board fuse (3 A)

ACCESSORIES/OPTIONS

In addition to the standard components, the machine can
be equipped with the following accessories/options,
according to the machine specific use:
GEL batteries
Electronic battery charger, if not supplied with the
machine
Main and side brooms with harder or softer bristles
Antistatic polyester or polyester BIA C dust filter
Manual vacuum system
Working light
Pivoting light
Skirts of various materials
For further information concerning the optional
accessories, contact an authorised Retailer.
146 2596 000(3)03-2016
USER MANUAL

USE

WARNING!
On some points of the machine there are
some adhesive plates indicating:
– DANGER
– WARNING
– CAUTION
– NOTE
While reading this Manual, the operator must pay
particular attention to these symbols.
Do not cover these plates for any reason and immediately
replace them if they are damaged.
BATTERY CHECK/SETTING ON A NEW
MACHINE
The machine requires two 12 V batteries or four 6 V
batteries connected according to the diagrams (20, Fig.
U).
The machine can be supplied in one of the following
modes:
a)
WET or GEL batteries already installed on the
machine
1. Open the machine hood (10, Fig. C) and engage
the hood support rod (3, Fig. U), then check that
the batteries are connected to the machine with
the connector (6, Fig. U).
2. Disengage the support rod and close the hood.
Check that the hood is properly closed (the
machine must be as shown in Fig. C).
3. Insert the key into the ignition switch (2, Fig. B)
and turn it to "II" position (without pressing the
pedal (5, Fig. C)), then release it. If the green
warning light (5, Fig. B) turns on, the batteries are
ready to be used. If the yellow (4, Fig. B) or red (3,
Fig. B) warning light turns on, it is necessary to
charge the batteries (see the relevant procedure
in the Maintenance chapter).