Herunterladen Inhalt Inhalt Diese Seite drucken

Oerlikon GC-Serie Betriebsanleitung Seite 68

Extruderpumpen mit elektrischen heizplatten
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5. Checking the operating readiness
Table for 5.1.3.
Operating parameters for extruder pump
parameters
permissible operating value
P
, pump inlet
Minimum values:
E
pressure
0.5 - 5
5 - 50
> 50
> 500
P
, pump inlet
Maximum value:
E
pressure
according to pump character­
istic data sheet.
P
, pump
Maximum value:
A
outlet
according to pump character­
pressure
istic data sheet.
T
, melt inlet
Minimum value:
E
20°C higher than
tempera-
melting temperature of
ture
conveying medium
T
, heating
Maximum value:
H
350 °C
plate tempera­
ture
M
drive
Maximum value:
d,
torque
The 1,2 times of the max.
torque, but not higher than
90% of the admissible pump−
drive torque. according to
characteristic data sheet.
d
=P
-P
,
Minimum value:
P
A
E
pressure
0.5 - 5
difference
5 - 50
between
> 50
pump
> 500
outlet and
inlet
Page
62
Customer:
Basis Version 05
reaction if values are
exceeded or not
reached
Alarm if not reached
Pas:
3 bar
minimum value for a
Pas:
5 bar
period of more than 2
Pas:
10 bar
minutes.
Pas:
30 bar
Alarm and switch-off
extruder drive if max.
value is exceeded.
Alarm and switch-off
extruder and pump
drive if max. value is
exceeded.
Unblocking of drive
at the earliest 1 hour
after achieving mini­
mum value.
When the max. tem­
perature is reached,
power supply is shut
off.
Disengaging of the
safety clutch or elec-
trical switch−off
Alarm if value not
Pas:
2 bar
reached for a period
Pas:
5 bar
of more than 5 min­
Pas:
10 bar
utes.
Pas:
30 bar
possible danger
Pump filling at the inlet is not
sufficient. Due to this reason,
possible reduction of supply to
the pump and of the bearing
lubrcation flow (insufficient lu­
brication of bearing)
Pump is overloaded
Pump is overloaded
Below the melt temperature,
the polymer is so hard that the
pump cannot be rotated or
could even be destroyed
Possible damage to the hea­
ting plates
Possible damage to pinion and
pinion shaft
Not enough conveying medium
flowing though bearing bushes,
i.e. lubrication is not sufficient.
Order:
000000-000
Edition:
01.20

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis