Oerlikon GC-Serie Betriebsanleitung Seite 58

Extruderpumpen mit elektrischen heizplatten
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4. Erection and Installation
Connecting the heating plates to the power supply system
Pump types GCB51K, GCV50K, GCV90K, GCH18K, GCH35K, GCH50K,
Pump types GEV50K, GEV90K, GEH18K, GEH35K, GEH50K:
– The heating plates are connected in series as shown in the adjacent illustration.
Information on the heating capacity can be found in the pump data sheet (see information in
Chapter 8.1.1).
Information on the heating capacity, the connection of the heating plates, and the connection voltage
can also be found on the pump drawing.
Pump types GCH75K, GEH75K:
The heating plates are connected in parallel as shown in the adjacent illustration.
Information on the heating capacity and the connection voltage can be found in the pump data sheet
(see information in Chapter 8.1.1).
Information on the heating capacity, the connection of the heating plates, and the connection voltage
can also be found on the pump drawing.