Herunterladen Inhalt Inhalt Diese Seite drucken

Malfunctions: Causes And Elimination; Table Of Malfunctions - Elmo Rietschle VLR 1000 HV+ Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Malfunctions: Causes and elimination

8
Malfunctions: Causes and elimination
DANGER
8.1

Table of malfunctions

Malfunction
The machine is
switched off by the
motor protection
switch
Pump does not start
Suction capacity is
insufficient
40
|
www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH
Prematic AG, Märwilerstrasse 43, 9556 Affeltrangen www.prematic.ch
Risk of injury!
If malfunctions are disregarded and/or removed only insufficiently, serious to
lethal injuries can occur.
Ø Never put the vacuum pump in operation again after it has been switched off
automatically without unequivocally finding out the reason for this shut-off
and remedying it.
Cause
Mains voltage / Frequency
does not correspond with the
motor data
Connection to motor terminal
board is not correct
Motor protection switch is not
set correctly
Motor protection switch is trig-
gered too quickly
The Emergency Stop
push-button has been
actuated
Release switch not switched
on
Malfunction of the frequency
converter
Pressure below setpoint value
The micro filter is dirty
The inlet pipe is too long or too
narrow
Machine or system leaking
Pressure sensor wrongly
scaled
Elimination
Check by qualified electrician
Use a motor protection switch
with an overload-dependent
turn-off delay that consid-
ers the short excess current
at start up (version with short
circuit and overload trigger
as per VDE 0660 Part 102 or
IEC 60947-4-1)
Unlock the Emergency Stop
button
Switch on release switch
Check the status LED on the
frequency converter. If neces-
sary, disconnect the converter
from the power supply for 30 s
Wait until pressure has
reached the minimum pressure
and restarts automatically. If
necessary, ventilate system.
Clean / replace the micro filter Chapter 7.2.2
Check the hose and/or the
pipe
Check the pipework and screw
connections for leaks and
check for tight fit
Re-scale pressure sensor
Tel. 071 918 60 60, Mail: v-g@prematic.ch
Note
Chapter 5.5
Chapter 6.2
Operating instruc-
tions of the fre-
quency converter
Chapter 4.2
Chapter 7.4
Chapter 5.3
Chapter 7.2
Elmo Rietschle
Service