NOTICE
1
s
1
1
Inlet flange
2
Compressed air
Fig. 19 Clean micro filter
The micro filter installed on the inlet side (Fig. 19/S) must be cleaned by rinsing out or blowing off or re-
placed more or less often depending on how dirty the sucked-in medium is.
a) Release the screws (Fig. 19/s
the inlet opening.
b) Remove and clean the micro filter (Fig. 19/S).
Also check the valve seat for contamination.
c) Re-insert the cleaned micro filter (Fig. 19/S) and remount the inlet flange (Fig. 19/1) on the inlet opening
using the screws (Fig. 19/s
7.7
Motor and coupling
7.7.1
Motor
Perform the maintenance of motors in accordance with the manufacturer's operating and mainte-
nance instructions.
Regularly clean the fan hood and the cooling ribs of the motor to ensure sufficient cooling for the motor.
7.7.2
Coupling / Fan
The fan (Fig. 20/v) for cooling the pump must be checked for tight fit and damages at least 1 x per year. If
necessary, the screw connections must be retightened or the fan is to be replaced.
Prematic AG, Märwilerstrasse 43, 9556 Affeltrangen www.prematic.ch
Property damage due to insufficient maintenance of the air filter!
Performance of the machine is reduced by a polluted air filter and insufficient
maintenance. This can cause damage of the machine.
Ø Regularly clean the mesh filter.
Ø Replace highly polluted or damaged mesh filters.
S
) on the inlet flange (Fig. 19/1) and carefully place the inlet flange next to
1
).
1
S
s
Screws
1
S
Micro filter