Commissioning and decommissioning
Fig. 11 Start screen
Legend for Fig. 11:
1
„Process (Prozess)" screen: Changing of setpoint values of pump pressure
2
„Analog input (Analogeingang)": Selection of types of analog inputs and input min./max. Value of sensor
3
„Limit values (Grenzwerte)" screen: Input min./max. Value of setpoint pressure
4
„PID" screen: Adapt PID-P/ PID-I/ PID-D values, input PID standby time, PID standby hysteresis and
5
„Time (Uhrzeit)" screen: Setting of date and time
6
„Password (Passwort)" screen: Setting of access rights
7
„Timer (Zeitschaltuhr)" screen: Setting of timer
8
„Contact (Kontakt)" screen: Display of contact address and software version
9
Status line: It displays current messages
10 „Home" pictogram: Jumps back to the Start screen
a) Select the „Password (Passwort)" screen on the Start screen (Fig. 11) (also see chapter 6.3.2).
b) Select the access level „Commissioning (Inbetriebnahme)" in the drop-down menu and the password
„1499" for this access level.
If the password is correct, the input field will turn to green.
c) Press on the pictogram „Home" to get back to the Start screen.
d) Select the „PID" screen on the Start screen (Fig. 11) (also see chapter 6.3.3).
e) Adapt the parameters as required. Make changes in small steps only and check before changing further
parameters.
f)
After parameterisation has been completed the pump will be ready for operation.
24
|
www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH