The diverse displays and possible settings on the touchscreen of the control unit are described below. Only
those displays are described that are necessary and accessible for the operator.
6.3.1

Navigation and status line

Navigation takes place by direct selection (press the button) on the pictograms displayed Start screen.
Leave the screen using the pictogram „Home" (Fig. 11/10) and display the Start screen again.
In the status line (Fig. 11/9), diverse status messages are displayed for the operator. The status messages
are shaded by colours that indicate the message in this way.
Colour
Red
Orange
Yellow
Blue
Green
Grey
The following status messages can be displayed:
Display
Emergency Stop pressed
(Not-Halt gedrückt)
Error ELCB
(Fehler FU)
Communication error CAN
(Kommunikationsfehler CAN)
Communication error RS485
(Kommunikationsfehler RS485)
Reset release
(Freigabe zurücksetzen)
Initialisation is running
(Initialisierung läuft)
Service required - contact
manufacturer
(Service notwendig - Hersteller
kontaktieren)
Timer is activated
(Zeitschaltuhr aktiviert)
External control active
(Externe Steuerung aktiv)
Maintenance required - see
Operating Instructions
(Wartung notwendig - siehe
Betriebsanleitung)
Please find a detailed description of the possible malfunctions and their elimination in chapter 8.
Prematic AG, Märwilerstrasse 43, 9556 Affeltrangen www.prematic.ch
Meaning
Malfunction
Warning
Process / operating error
Info / note
Automated process
Maintenance
Meaning
Emergency Stop push-button actuated and must be unlocked
The frequency converter reports a fault condition
CAN message from master or its heart-beat signal failed
RS485 message from master or its heart-beat signal failed
After the Emergency Stop signal has been unlocked, the release must be
reset: Switch the release switch off and on again.
Modbus communication to frequency converter has not been completed
The unit needs to be checked. Contact Elmo Rietschle Service.
Timer is switched on.
The setpoint value is input to the frequency converter via the CAN master
The pump has to be serviced