Transport, storage and disposal
a) The central vacuum unit is supplied on a Euro pallet. Unload the central vacuum unit out of the transport
vehicle and transport it by fork lift or pallet truck to the place of installation.
b) Tighten the eyebolts (Fig. 1/1) and fixing screw on the transport shackle (Fig. 1/2) firmly.
c) For lifting and transporting of the machine it must be hooked in the eyebolts and the transport shackle
using a lifting tackle.
In case of longer transports, put the pump in a transport crate or on a pallet. With this, secure the pump
against tipping over and slipping away!
3.2

Storage

NOTICE
3.2.1

Ambient conditions during storage

Ambient conditions
Relative humidity

Storage temperature

The central vacuum unit must be stored in a dry environment with normal air humidity. It should
not be stored for more than 6 months.
 See Info "Storage instructions", Page 4
12
|
www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH
Prematic AG, Märwilerstrasse 43, 9556 Affeltrangen www.prematic.ch
Material damage caused by improper storage!
Improper storage can damage the machine.
The storage area must meet the following conditions:
Ø Dust-free
Ø Vibration free
Value
0 % to 80 %
-10 °C to +60 °C