3.6 Checks after the first start

Malfunctions of the machine:
Pull the power supply plug. Turn the phase changer around 180º at the power supply plug with
a screwdriver.
WARNING!
If machi ne functions are blocked, switch off the machine immediately!
Long operation of the pump in false direction of rotation leads to the total failure
of the pump!
Turn the main switch to the right on position "On".
Press the button "I" (ON). The button lights up, if the machine is ready
for use.
Before pressing the button "R" (RESET) the tools must be
inserted into the machine. Otherwise the button "R" (RESET)
flashes fast.
Press the button "R" (RESET). The machine accomplishes an
automatic tool recognition. Keep pressed the button until the
button lights up.