Herunterladen Inhalt Inhalt Diese Seite drucken

Iberital Expression Pro Installations- Und Betriebshandbuch Seite 91

Espresso coffee machine
Vorschau ausblenden Andere Handbücher für Expression Pro:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 227
Once this procedure is completed, press the MENU button to move on to the following option:
* The "STEAM BOILER" OPTION IS NOT AVAILABLE and will always leave the factory set at "O" (NOT AVAILABLE).
Once this procedure is completed, press the MENU button to move on to the following option:
The display will give the option of ENABLING or DISABLING the "PRE-BREW" function using the UP/DOWN buttons.
ACTIVATING the "PRE-BREW" function and pressing the MENU button, the display will show:
The display will show the timer option for 'PRE-BREW ON' for each coffee selection (1 espresso, 1 coffee, etc.). Pressing
the UP/DOWN buttons, the desired time in seconds (from 0.1 sec. to 5 sec. in jumps of 0.1 sec.) can be selected. Press the
MENU button to select the 'ON' times for the rest of the selections.
Once this procedure is completed, press the MENU button to move on to the following option:
The display will show the 'PRE-BREW' timer 'OFF' option for each coffee selection (1 espresso, 1 coffee, etc.). Pressing
the UP/DOWN buttons, the desired time in seconds (from 0.1 sec. to 5 sec. in jumps of 0.1 sec.) can be selected. Press the
MENU button to select the 'ON' times for the rest of the selections.
Once this procedure is completed, press the MENU button to move on to the following option:
The display will show the "PROBE SENSITIVITY" option for the level of water in the boiler. Press the UP/DOWN buttons
to select low (150KΩ), medium (400KΩ) or high (1 MΩ) sensitivity.
Once this procedure is completed, press the MENU button to move on to the following option:
The display will show the 'SERVICE CYCLES' option when the machine reaches the number of cycles selected. It will send
a visual alarm on the display as notification. Pressing the UP/DOWN keys selects the number of cycles.
Once this procedure is completed, press the MENU button to move on to the following option:
The display will show the machine heating control system option.
Press the UP/DOWN buttons to select "Pressure Switch", "ON/OFF" or "PID" and confirm by pressing OK.
INSTALLATION AND OPERATION MANUAL
Steam Boiler Gr.
O/1/2
Option is not available
PreBrewing
ENABLED/DISABLED
PreBrew. ON
1 espresso xxxx sec
PreBrew. OFF
1 espresso xxxx sec
ProbeSensitivity
LOW/MID/HIGH
Service Cycles
xxxxxxx
Heating Type
xxxxxxx
xxxxxx: Pressure Switch, ON/OFF, PID
IBERITAL
89

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

NewTandemIntenzIb7

Inhaltsverzeichnis