NOTE
On all machines there is a high-limit thermostat to control the temperature of the heating elements
electrically: this thermostat limits the elements' temperature. When the temperature is above the
maximum level, the electrical power supply to the elements is cut. When this happens, the thermostat
must be reset by pushing the button located on it, once the element is cold. (The thermostat can be
accessed by removing the right panel on the machine.) In the case of machines with two boilers, there is
one for each element.
NOTE
All machines have a boiler level sensor. For machines with two boilers, the sensor is in the steam/hot
water boiler.

3.2. WATER SUPPLY CONNECTION

IMPORTANT
This equipment must be installed in accordance with applicable federal, state or local regulations.
The machine has a 3/8" water inlet for the water supply. The said inlet incorporates a stop tap to open or close the flow
of water (optional). Likewise, hoses are included. To be correctly installed, the mains water supply stop tap will have to
be connected to the previously mentioned inlet on the machine using one of these hoses, or similar.

3.3. CONNECTION TO THE POWER SUPPLY

IMPORTANT
This equipment must be permanently connected to the power supply.
The machine is equipped with elements and other electrical parts at 110 V, 220 V - 240 V depending on the version.
A switch must be installed, of a suitable calibre, between the permanent installation and the machine. The maximum
electricity consumption is indicated on the rating plate.
The earth cable must be connected to an efficient earth.
IMPORTANT
The machines can only be connected to 110 V, 220 V - 240 V depending on the version of the
machine.