Group 1
Group 2
Pre-brewing:
Group 3
All groups
Group X
1 espresso
Pre-brewing
ON: 0.6 s
OFF: 1.8 s
program:
Group X
1 espresso
Pre-brewing
OFF: 1.8 s
program:
Enabled
Continuous
key:
Disabled
- ALARM CONFIG: Through this menu, we can edit the alarm notifications related to machine
maintenance and filters.
Services
cycles
Water filter
Alarm for
00000
service
cycles:
Alarm
00000
for water
filter:
2.9.3.2.3. Display alarm signals
A. MAXIMUM FILLING TIME FOR BOILER WATER
When a time set by the manufacturer is exceeded, the display will show:
Alarm:
Boiler filling time out.
B. MAXIMUM BOILER TEMPERATURE
The display will show the boiler temperature alarm when it exceeds 140ºC for more than 5 seconds.
Alarm:
Boiler temperature.
C. INTERRUPTED TEMPERATURE SENSOR
When the sensor detects a temperature of 0ºC for 5 seconds, the LEDs on the button pads will flash and the display will
show:
Alarm:
Temperature probe failure.
INSTALLATION AND OPERATION MANUAL
ON:
0.6
s
To cancel the alarm, the main switch must be set to O and then to 1
The alarm will disappear when the boiler temperature returns to its
normal values.
The alarm will disappear when the boiler temperature is once again
at an acceptable value.
Depending on the option selected, we can modify, either
individually or as a whole, the pre-brewing time.
By pressing the
icon, we can go through the various
coffee service types.
We can modify the ON/OFF time for the previously
selected service.
Depending on the option selected, we have the option of enabling
or deactivating the use of the non-stop coffee-making button.
We can modify the number of services after which an alarm
notification will appear, reminding us to carry out the appropriate
maintenance every "x" number of services.
We can modify the number of services after which an alarm
notification will appear, reminding us to carry out the regeneration
or change of the descaler filter.