Connection of Telemetry Devices to COM2

Siemens Building Technologies
Fire Safety & Security Products
Interface adjustment (these settings must also be made on the SISTORE AX)
Baud rate: 19200
Parity:
none
Required settings (SW401) for use of output COM1B as RS232 interface
Required accessories
RS485 cable: 2-core shielded, maximum permissible length 1.2 km.
9-pin Sub-D plug with housing.
OFF
1
4
7 8
Parameter menu
-> Interface adjustment
Fig. 16
Example: Setting and parameterization with connection of SISTORE AX
to COM1B
Interface adjustment (these settings must also be made on the SISTORE AX)
Baud rate: 19200
Parity:
none
Via the telemetry interface, the Control Unit CKA4820 permits control of the
following SIEMENS devices, amongst others:
SIEMENS camera control and power supply units SCUxxx
SIEMENS camera control and power supply units CDCxxx
SIEMENS DOME systems CCDAxxx
SIVIS MINI DOME systems with DCU function module
SIEMENS DOME systems CCDAxxx and SIVIS via CAC0103 interface
Digital cameras with CAC0101 interface connection
Interface adjustment
-> Mode COM1 -> SISTORE AX COM1
System Design
75
01.2005