Operation Level Changeover; Electronic Volume Sensitivity Changeover - Balluff BOS 73K-Serie Bedienungsanleitung

Federspanner
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

"S" Manual setting for operation level/sensitivity
( Function )
5a) Operation level changeover
On - operation level can be changed both for Light - On and Dark - On
operation.
Light - On : On value when light enters.
Dark - On : On value when light is interrupted
Push button 2 several times until the digit to be changed flashes.
Push button 1 to count up the flashing figure.
After setting is completed, replace the switch
to RUN. The changeover is completed.
Addition
- Operation level changeover range: Light - On: 9 to 999
- OUT is shown for out of changeover range.
If the switch is replaced to RUN for completion with OUT remained to be
shown, the set value is canceled.
- Hysteresis is automatically set at "4".
- When both of operation level and hysteresis level are changed,change hysteresis
level ( See page 25 ) after the operation level has been changed according to the above.
5b) Electronic volume sensitivity changeover
Push button 2 several times to flash electronic
volume figure.
Push button 1 to count up the flashing figure.
The display shows incoming light level at the selected volume value.
After selection is completed, replace the switch to RUN
22
Dark - On: 5 to 995
SELECT
RUN
MODE
SELECT
RUN
MODE
SELECT
RUN
MODE