Herunterladen Inhalt Inhalt Diese Seite drucken

Startup And Operation; Startup; Operation; Operating Notes - Balluff BOS R080K-XM-RS10-S4 Serie Betriebsanleitung

Vorschau ausblenden Andere Handbücher für BOS R080K-XM-RS10-S4 Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
BOS R080K-XM-RS10-(...-)S4 / BOS R080K-UIM-RE10-(...-)S4
Photoelectric Sensors
6

Startup and operation

6.1

Startup

DANGER
Uncontrolled system movement
When starting up, if the sensor is part of a closed loop
system whose parameters have not yet been set, the
system may perform uncontrolled movements. This
could result in personal injury and equipment damage.
► Persons must keep away from the system's
hazardous zones.
► Startup must be performed only by trained technical
personnel.
► Observe the safety instructions of the equipment or
system manufacturer.
CAUTION
Red light
If you look into the light beam, temporary blinding and
irritation of the eyes is possible.
Use of Controls or adjustment or performance of
procedures other than those specified herein may result
in hazardous radiation exposure.
► Do not look into the light beam!
► Observe the instructions in this manual.
1. Check connections for tightness and correct polarity.
Replace damaged connections.
2. Turn on the system.
3. Check measured values and adjustable parameters
and realign and adjust the sensor, if necessary.
Check for the correct values, especially after
replacing the sensor or after repair by the
manufacturer.
www.balluff.com
6.2

Operation

CAUTION
Red light
If you look into the light beam, temporary blinding and
irritation of the eyes is possible.
Use of Controls or adjustment or performance of
procedures other than those specified herein may result
in hazardous radiation exposure.
► Do not look into the light beam!
► Observe the instructions in this manual.
No other protective measures are required (Exempt Group
per IEC 62471).
6.3

Operating notes

Regularly check function of the sensor and all
associated components.
Take the sensor out of service whenever there is a
malfunction.
Secure the system against unauthorized use.
Check fasteners and retighten if needed.
6.4

Cleaning

Keep the lens as free from soiling as possible (dust etc.)
and do not touch it (fingerprints).
Remove soiling
► Wipe off the lens with a lint-free cloth and alcohol
(ethanol, isopropanol).
6.5

Maintenance

The product is maintenance-free.
english
9

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Bos r080k-uim-re10-s4 serieBos r080k-xm-rs10-s4Bos r080k-uim-re10-s4

Inhaltsverzeichnis