Specifications
Model
PNP type
Detection
Range
Power supply
Current consumpion
Output
Output
mode
Stability Output
Operation mode
Timer
Response time
Light source
( wave length )
Indicator
Display
Switch
Teaching input
Features
Material
Wiring
Weight
Ambient illumination
Ambient temperature
4
BOS 73 K-PU-1FR-C-02
Through beam / Reflection (by fiber unit)
11 ... 26 V DC
P N P : Source current 100mA (30VDC) Max. Residual voltage: 2V or less
P N P : Source current 50mA (30VDC) Max. Residual voltage: 2V or less
Light - On / Dark - On selectable
On delay / Off delay / On - Off delay / non - delay selectable
Timer time: 10 / 20 / 40 / 60 / 80 / 100 / 120ms selectable 40ms. set at factory
Transmission frequency Channel 1:500ms or less
Operation indicator: Orange LED Stability indicator: Green LED
Setting button:2 Operation changeover switch: RUN/SELECT/MODE
Setting button / External input
- Sensor feature: Auto sensing / Teaching / Locking
- Accessory feature:S - Manual setting for sensitivity / ON - operation level
H-manual setting for hysteresis
V-Light variation indication mode / Absolute value
- Interference protection buil - in
- Self - diagnostic built - in
- Short curcuit protection built - in
Cable 0. 2sq. 5 core 2m length Pigtail with M8 connector 4-pole
Approx. 80 ( including mounting bracket )
Incandescent lamp: 10,000 lx or less Sun light: 20,000 lx or less
-25 °C to +55 °C ( storage: 40 °C to +70 °C )
in case of installed some pieces closely, 1 - 4 pcs: -25 °C to +55 °C
BOS 73 K-PU-1FR-S75-01
Depending on fiber unit
Ripple < 10%
50mA or less
Open collector
Open collector
Channel 2:600ms or less
Red LED (660nm)
LCD with back light
indication mode
Polycarbonate
5pcs or more: -25 °C to +45 °C