Herunterladen Inhalt Inhalt Diese Seite drucken

How To Indicate Absolute Value ( V ) - Balluff BOS 73K-Serie Bedienungsanleitung

Federspanner
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

"V" How to indicate absolute value
( Function )
Useful to compare the incoming light amounts ( light - in ) with the amounts
( light-interrupted ) when the light amount differential is undiscriminating
on normal mode due to volumes of incoming light.
( Ex. When the light level indication ( light-in ) is saturated, etc. )
Incoming light level is shown in the range of 0 to 9999 regardless of the
indication for electronic volume sensitivity. ( Incoming light level is shown
regardless of output. )
1) Turn the switch to SELECT to show SELE.
2) Push button 1 select "V". Turn the switch to MODE.
SELECT
RUN
The present light
level is indicated.
Addition
- Push button 1 to change dynamic range width.
- After the indication is saturated up to 999, push button 1 for further indication.
- U shifts to u and light amount can be shown further. In this stage, the Max.
indication is also 9999 max.
Push button 1 after saturated.
The indication will shift U - u - U whenever button 1 is pushed.
A number in single figure may flicker. Use it as a reference to
compare light amounts.
SELECT
RUN
MODE
MODE
" " is shown
V
‚ u ‚ u
RUN
BOS 73
incoming light level
The width is miniaturized for an
additional indication.
SELECT
MODE
25