"H" Hysteresis selection
( Function )
Off operation level can be changed with On operation level fixed.
Hysteresis = On operation level - Off operation level
Hysteresis changeover ranges 1 to 99.
00 is impossible to be set. This results in "out of range".
Min. hysteresis value set on teaching mode is "4".
1) Turn the switch to SELECT.
2) Push button 1 and select "H". Turn the switch to MODE.
SELECT
RUN
3) The flashing digit is possible to be changed.
- Push button 2 to shift digit.
- Push button 1 to count up the flashing figure.
4) Replace the switch to RUN after setting is completed.
Note
Setting hysteresis value less than required may cause chattering
due to external lights, noise etc.