Timer time changeover
Timer is factory set at 40ms.
Any of 10ms, 20ms, 40ms, 60ms, 80ms, 100ms, 120ms. is available.
1) Confirm the switch is positioned on RUN.
2) Turn the switch to SELECT
while pushing button 2.
3) Release the button 2, and the present timer is shown together with
a indication of "o-n-d-o-F-d".
4) The timer time will change to show
whenever button 1 is pushed.
Select the required time.
5) After selection is completed, replace
the switch to RUN.
14
SELECT
RUN
MODE
SELECT
RUN
MODE
SELECT
RUN
MODE
Shows present timer
time is 40ms.
SELECT
RUN
MODE