Herunterladen Inhalt Inhalt Diese Seite drucken

Product Description; General Product Overview; Technical Data; Rating Plate - Novoferm iso70-1 TW Montage- Und Betriebsanleitung

Sektionaltore mit torsionsfederwelle
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
Risk of injury due to high rope
WARNING
tension
The ropes are under high tension. Dam-
aged ropes can tear and cause severe
injuries.
Prior to replacing damaged ropes or
springs, secure the door against un-
controlled movements.
Regularly check the ropes. Dam-
aged ropes must be replaced imme-
diately.
3

Product description

3.1

General product overview

Fig. 1: Product view
VL
Fig. 2: Front-mounted torsion spring shaft (VL version)
Fig. 3: Rear-mounted torsion spring shaft (HL version)
HL
3.2

Technical data

Model specifications
Product:
Door size / weight
Temperature range:
Sound pressure level L
Manufacturer:
3.3

Rating plate

The rating plate is situated on the inside of the door
leaf.
4

Mounting

4.1
Safety information for installation and
assembly
The installation may only be carried out by
suitably qualified installers, see chapter 2.3 -
Personnel qualifications.
Read these installation instructions before you
start installing the product.
Never carry out the installation on your own.
Some of the work steps can only be achieved
with two people working.
4.2

Scope of delivery

The scope of delivery is determined by the product
configuration. The scope of supply usually comprises
the following:
Packet with sections
Packet with frame
Packet for installation
4.3

Preparing for installation

4.3.1 Information regarding installation
Observe the following information before starting the
installation:
The steps for installation described in these
assembly and operating instructions refer to a
standard installation. Please contact the
manufacturer regarding special mounting
conditions.
Note that the following assembly instructions
describe the assembly of a sectional door with a
front-mounted torsion spring shaft (VL). If a rear-
mounted torsion spring shaft (HL) is to be
mounted, also observe the instructions in
chapter: 4.7 / – Mounting the rear-mounted
torsion spring shaft (HL).
iso70-1
see rating plate
+40 °C
-20 °C
≤ 70 dB(A)
pA
Novoferm GmbH
Isselburger Straße 31
46459 Rees (Haldern),
Germany
Germany
www.novoferm.de
EN - 21