Herunterladen Inhalt Inhalt Diese Seite drucken

Data Mapping (Sources Configuration) - OSRAM e:cue SYMPL bridge Node Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Output configuration
the connected fixture address consumption to get a seamless e:pix
universe: for each port, take the amount of fixture consumed channels
(length) of four DMX universes (1 ... 512 for part 1 to part 4). If not the
full e:pix universe (the sum of all four parts is smaller than 2048) is used,
remaining parts can be set to 0 in order to avoid possible waiting time
for complete data input.
Click the "switch to DMX" button to change the protocol type to the
DMX512 standard. Only one length of maximum 512 channels will be
available for each output port.
3.
After configuring all ports, click the "submit" button to save the
configuration.
6.2

Data mapping (Sources configuration)

The second step of the output configuration is to configure the data input.
The SYMPL bridge Node provides two data input sources. For each
source, configure first its protocol and parameters.
Protocol
sACN
Art-Net
e:net
Then map the input data to the previously configured output ports:
Universe a
Universe b
Universe c
Universe d
24
Source
Port Number
1, 2
5568
1, 2
6454
1
-
Source 1
take (len1) channels
starting at offset1
take (len2) channels
starting at offset2
take (len3) channels
starting at offset3
take (len4) channels
starting at offset4
Data mapping
yes
yes
no
Port x
e:pix output for Source 1
Part 1
(len1)
Part 2
Part 3
(len2)
(len3)
Part 4
(len4)

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Am356970031

Inhaltsverzeichnis