6.1

Ports configuration

The first step of the output configuration is to configure the channel size of
the eight output ports. The channel size is equivalent to the channel count
of the connected fixtures to each port:
Source 1
take (len1) channels
Universe a
starting at offset1
take (len2) channels
Universe b
starting at offset2
take (len3) channels
Universe c
starting at offset3
take (len4) channels
Universe d
starting at offset4
1.
Open the ports configuration page by selecting "Output
Configuration" on the left side of the web interface of the
SYMPL bridge Node:
1.
2.
Select the type of protocol the connected fixtures support. You can
address up to 4 x 512 DMX channels (=2048) by one e:pix port. Map
Port x
Part 1
(len1)
2.
3.
Output configuration
e:pix output for Source 1
Part 2
Part 3
(len2)
(len3)
Part 4
(len4)