2.4
Identify button: Identification & Reset
The Identify button has four functions: to send an Identify message (A), to
reset the Node (B), and to exit the error state (C). The Identify button
additionally switches protocol during Test mode (D).
(A) Only available with e:net: A short press during operation in online mode
sends an Identify message to the server. This helps to assign the Node in
the Setup tab in SYMPHOLIGHT.
(B) The Identify button can also be used to reset the device to factory state
or to stay in bootloader mode. With a reset you restore the password and
device settings by using the Identify button. Please note that the device
name is not reset:
Keep the Identify button pressed while powering up, Status and
Test / Error LEDs light up at first. Bootloader mode is signaled by a fast
blinking Status LED. Release the button now. The device stays in
bootloader mode to download a new firmware.
To exit the bootloader mode, short press the Identify button again.
Press the Identify button during operation until Status and
Test / Error LEDs blink alternating, then blink together. Releasing the
button now resets the device to its factory settings. The password and
network settings are reset to their default values. Please note that the
device name cannot be reset.
Keeping the button pressed further on, the device proceeds to
normal operation. No changes apply.
(C) Short press the Identify button if an error occurs and you want to exit
the error mode. The device will switch back to normal activity if the cause of
error is eliminated. The Node might reboot.
(D) During test mode, single press the Identify button to switch between
e:pix and DMX protocol in the test.
General device description