7.3
Cleaning the grease separator
•
Carry out the tasks that are described under 4.3 Disposal (discharging the sludge trap and the grease
separator).
•
Make sure that no more wastewater can be supplied.
•
Disconnect the power supply.
•
Remove the maintenance cover from the sludge trap <23>.
•
Remove the maintenance cover from the Ballance tower <30>.
•
Discharge the grease separator; to do so, extract the wastewater from the Ballance tower <31>
•
Remove the heating cover ventilation <36>.
16
•
Disconnect the heating cover power supply <41>.
•
Open the grease separator clamping ring <49> and remove the heat-
ing cover<42>.
•
Remove any grease residue mechanically from the heating cover
from the inside (e.g. with a wooden or plastic spatula, no metal).
Do not clean the grease separator with a water pressure
higher than 5 bar and a water temperature higher than 50°C.
Do not apply a high-pressure cleaner to the seals. If soap
has been used for cleaning purposes, rinse out/extract the
residue as it could lead to malfunctions.
Maintenance
36
30
35
ÀJ
72 / 80
16
ÀJ
41
23
30
35
31
42
49
ÀJ
2016/05