4.2

Installing the pipes

Connecting the riser pipe/disposal pipe
Undo the pipe clamps at the end of the direct disposal
pipe.
Connect the riser pipe (HDPE) provided by the customer
to the direct disposal pipe.
Attachment of the refill inlet
Pull clips off the attachment clamp.
Pull the refill inlet pipe out of the attachment clamp.
Insert the refill inlet pipe with pre-assembled seal into the
opening for pipe penetration.
Slide in the refill inlet pipe in such a way that it can be
fixed in place with the attachment clamp.
Attach clips to the attachment clamp.
✓ Refill inlet is ready for operation.
The supply pipe to the refill inlet must be routed in such a
way that dormant lines are avoided. The risk of contami-
nating the lines with legionella should be excluded as far
as possible.
4.3
Mount the accessory parts
Inspection window (optional)
If there is no inspection window on the system, an inspection window can be retrofitted by the KESSEL Factory Customer
Service on request.
Connecting Storz-B coupling
Connect the Storz-B coupling to the riser pipe/disposal pipe provided by the customer.
If the Storz-B coupling is to be positioned at some distance outside the building, the KESSEL disposal chamber (acces-
sory) can be used for this.
22 / 82