► Set the socket flexion β so that the lateral socket reference point 
erence line.
INFORMATION: If the socket reference point 
line with the adapters that are installed, special adapters have to be used (
adapters).
Socket adduction
► Based on the socket length, determine the required angle γ 
reconcile this with a possible residual limb malposition.
► Set the socket adduction γ so that the frontal socket reference point 
reference line.
INFORMATION: If the socket reference point 
line with the adapters that are installed, special adapters have to be used (
adapters).

6.2.9 Shortening the tube adapter

CAUTION
Incorrect processing of tube
Fall due to damage to the tube
Do not clamp the tube into a vice.
For shortening the tube, use only a tube cutter.
INFORMATION: The overall system height of all prosthetic components corresponds to the sock­
et-floor measurement (see Fig. 
► Shorten and deburr the tube adapter.

6.2.10 Mounting the lock slide and lock release cable

► CAUTION! Use the lock slide only as shown in Fig. 
the lock release cable.

6.2.11 Preventing damage at maximum flexion

► NOTICE! Perform the steps shown in Fig. 
ion.

6.3 Optimising the static alignment

6.3.1 Checking the static alignment

► To check the static alignment, position the patient on the measuring device as shown in
24
Fig. 
on page 18.
6.3.2 Optimising the static alignment
► In the sagittal plane, check the course of the load line 
2
point 
and correct this as shown if needed (see Fig. 
► In the frontal plane, check the course of the load line 
3
thetic foot,
 prosthetic knee joint,
26
(see Fig. 
on page 19).

6.4 Optimising during dynamic trial fitting

6.4.1 Resetting to factory defaults

► Before performing the exercises in the sections that follow, reset settings that have been
changed to factory defaults according to Fig. 
44 | Ottobock
5
cannot be positioned on the alignment reference
9
cannot be positioned on the alignment reference
21
on page 16).
23
on page 17 to prevent damage at maximum flex­
4
 Spina iliaca anterior superior) and correct if needed
27
4
lies on the alignment ref­
7
for socket adduction, and
22
on page 17 and mount it together with
1
relative to the alignment reference
25
on page 18).
1
relative to the marked points (
on page 19.
6
 examples of
8
lies on the alignment
10
 examples of
2
 pros­