12.2 Securing the appliance to
the cabinet

12.3 Electrical installation

The manufacturer is not
responsible if you do not
follow the safety precautions
from the Safety chapters.
This appliance is supplied only with a
main cable.
min. 550
20
580
min. 560
9
12.4 Cable
Cable types applicable for installation or
replacement:
H07 RN-F, H05 RN-F, H05 RRF, H05
A
VV-F, H05 V2V2-F (T90), H05 BB-F
B
For the section of the cable refer to the
total power on the rating plate. You can
also refer to the table:
The earth cord (green / yellow cable)
must be 2 cm longer than phase and
neutral cables (blue and brown cables).
548
21
114
18
589
±1
595
Total power (W)
maximum 1380
maximum 2300
maximum 3680
ENGLISH
35
198
518
Section of the ca‐
ble (mm²)
3 x 0.75
3 x 1
3 x 1.5