Head comms signal booster box installation
When using the Renishaw high-speed communications cable (orange cable) with Renishaw's 5-axis products, the maximum permissible cable
length is 25 m. Where runs of greater than 25 m are needed between the machine controller and probe head, a head comms signal booster
(HCSB) must be inserted. One HCSB is required for each additional 25 m of cable run.
The HCSB is powered from the machine cable so does not require an additional power supply. It simply connects between two machine cables
as shown in the diagram below and can be attached to a suitable part of the machine structure if required.
Dimensions ﴾L × W × H﴿
Net weight
Power supply
Connectors
Issued 03 2019
Downloaded from
www.Manualslib.com
manuals search engine
91 mm × 64 mm × 32 mm
161 g
20 Vdc supplied via machine cable
15-way high-density 'D' type plug connects to cable from controller
15-way 'D' type socket connects to cable from head