REPLACEMENT

If there is any sign of wear or if the product or parts thereof are damaged, it must be replaced.
When the product has been replaced, observe the steps ASSEMBLY, LEAK TESTING and
START-UP. To ensure that the installation works faultlessly under normal operating conditions,
it is recommended to replace system parts subject to wear or ageing,
e.g. pressure regulators, hose assemblies, shut-off devices, as required:
• Recommendation: replacement times 5 years.
In case of continuous gas escaping via the pressure relief valve PRV via the breather the
pressure regulator must be replaced with a new pressure regulator.
In case of gas smells, leaks, gas escaping via the PRV or faults in the consumption
equipment, SHUT DOWN THE SYSTEM immediately. Contact a specialised company.
The gasket in the inlet connector (if provided) must be changed every time the cylinder has
been replaced or disassembled. It must also be replaced if it is damaged or the connection is
no longer tight.

SHUT-DOWN

Close the gas supply and then the shut-off fittings of the connected loads. When the LPG
system is not in use, all valves must remain closed.
Close all free connections in the feed lines of the LPG system tightly with a
suitable cap to prevent gas from flowing out.

TECHNICAL DATA

Inlet pressure p
Outlet pressure p
d
Nominal flow rate M
Maximum admissible pressure
Ambient temperature
Response pressure PRV
ΔP
Housing material
The operating pressure of the Caramatic BasicTwo (30 or 50 mbar see label on the
central controller
installed in the area of application in question!
The total quantity of all units must not exceed withdrawal quantity of 1.5 kg/h.
∆P = maximum permitted pressure drop in downstream installation. Refer to the type
label of the pressure regulator for more technical data and special settings!

DISPOSAL

To protect the environment, our products may not be disposed of along with
household waste.
The product must be disposed of via a local collection station or a recycling station.
part no. 02 018 51d
0.3 to 16bar
alternatively 30 or 50mbar
1,5 kg/h
g
PS 16bar
-20 °C to +60 °C
< 150mbar
5mbar at p
5mbar at p
ZP0410
) must correspond to the operating pressure of the devices
30mbar
d
50mbar
d
Caramatic BasicTwo
11 / 12