U10M, U10S
Nominal (rated)
force
Limit bending mo-
5)
ment
5)
Limit torque
Nominal (rated) dis-
placement
Fundamental reso-
nance frequency
Rigidity
Permissible vibra-
tional stress
(Vibration bandwidth
per DIN 50 100)
Weight
With adapter
Without adapter
Interference resistance
(EN 61 326-1, Table A.1)
Electromagnetic field (AM)
Magnetic field
Electrostatic discharge (ESD)
Contact discharge
Air discharge
Burst
(rapid transients)
Surge
(impulse voltages)
Grid-bound interferences (AM)
Mechanical shock
(Test severity level
IEC 68-2-29-1987)
Number
Duration
Acceleration
Vibrational stress
(Test severity level per
DIN IEC 68; Part 2-6;
IEC 68-2-6-1982)
Frequency range
Duration
Acceleration
Degree of protection per DIN
EN 60 529
1)
Option: Adjustment of sensitivity to 2 mV/V (or 1 mV/V).
2)
Reversibility error at 200% is typically the same as at nominal (rated) force.
3)
Pure lateral force relating to the link centre of the transducer.
4)
For transducer with adapter: 370 N@m.
5)
See Chapter 5.2.
6)
For the connected bayonet plug version.
A1385−6.0 en/de/fr
F
kN
1.25
nom
M
N@m
30
b adm
M
N@m
30
L
s
mm
nom
f
kHz
4.5
G
5
F/S
10
0.625 1.25 2.5 4.17
N/mm
% v.
F
F
rb
nom
kg
lbs
kg
lbs
V/m
A/m
kV
kV
kV
kV
V
n
ms
2
m/s
Hz
ms
2
m/s
2.5
5
12.5
25
60
125 315
635
60
125 315 635
0.02
0.03
5.9
9.3
6.6
9.2
8.33
1.2
3
2.65
6.61
0.5
1.3
1.1
2.87
Industrial environment
5 ... 65
IP67
50
125
250
1270 3175 5715
4)
1270 3175 5715
0.04
0.05
6.5
8.1
6.6
16.7 31.3
50.0
200
10
23
22.05
50.71
5
11
11.02
24.25
10
30
4
8
1
1
3
1000
0.5
1000
0.5
1000
6)
31
500
11430
11430
0.06
6.1
83.3
60
132.28
28
61.73
HBM