Herunterladen Inhalt Inhalt Diese Seite drucken

HBM U10M Montageanleitung Seite 10

Kraftaufnehmer
Vorschau ausblenden Andere Handbücher für U10M:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

10
Fig 1.1:
U10M with adapter (left) and without adapter (right)
2. Double bridge design
The force transducer is also available with two electrically isolated mea-
surement bridge circuits.
3. TEDS
You can purchase the force transducer with transducer identification
("TEDS"). TEDS (Transducer Electronic Data Sheet) allows you to store the
transducer data (characteristic values) in a chip, that can be read out by a
connected measuring device. Each measuring bridge has a separate TEDS
in the double bridge variant. See also Page 24.
4. Threaded connector
The force transducer is usually delivered with a bayonet connector. A
threaded connector can be mounted, if required.
5. Calibration:
On request, HBM can calibrate the force transducer to 200% nominal
(rated) force. The high mechanical reserves of the force transducer enable
this application in purely static measurement tasks. Please note however
that the output signal doubles.
6. Force application part
On request, we can deliver the U10M with a force application bolt mounted
in the central thread, see Fig 1.2 on Page 11.
HBM
U10M, U10S