AHT Cooling Systems GmbH

Complete defrosting

On devices with and without
We recommend combining the complete defrosting
with the basic cleaning.
Defrosting interval
For hygiene reasons, at least twice a year.
With devices from series (U/V):
Each time before switching to another operating
mode.
Carrying out a complete defrosting:
Mechanical
controller
1.
Move the goods to another device with the
same product temperature class.
2.
Switch the cooling function off
Press the
[DEFROST]
button. The green
lamp (3, 3a or 3b)
goes out.
See → Chapter
4.2.1
Remove the cover (see → Chapter 7).
3.
4.
Remove all accessory parts from the device
interior, e.g.: air ducts, shelf grille, goods grate.
The blower carrier remains in the device.
5.
Remove condensation water.
Devices of type R-404A: Wet vacuum cleaner
or sponge.
For devices of type R-290: Wet vacuum
cleaner/electrical devices with explosion
protection marking or slightly damp cloth
(observe the warning information, see →
Chapter 10).
Device with condensation water plug
(optional):
Place a collecting tray underneath the drain.
Remove condensation water plug.
Allow the condensation water to drain.
Close the condensation water plug again.
Condensatio
n water plug
Fig.13 Device with view of the condensation water
plug
6.
Clean the inside area and then wipe dry.
For devices of type R-290: Observe the
warning information, see → Chapter 10.
7.
Correctly reinstall all accessory parts.
Correctly install the cover (see → Chapter 7)
8.
and close completely.
9.
Switch on the cooling function
Press the
[DEFROST]
button. Lamp (3, 3a
on21.05.2018 21:36
(AD)
function.
Electronic controller
Press the [STANDBY]
button for at least 1
second or the [STANDBY
RESET] for at least 3
seconds. "---" is shown on
the display.
See → Chapter
4.2.2.1/4.2.3.1
Press the [STANDBY]
button for at least 1 second
or the [STANDBY RESET]
361929_0917_BA_SM_V4_06.09.2017_U_enUS_CD.docx
or 3b) lights up
green again. See
→ Chapter 4.2.1
NOTE
Property damage from foreseeable misuse.
►The device must only be loaded with goods when
the temperature specified for the product has been
reached.
With a complete defrosting, devices that are
connected via a bus system must remain on the power
supply and be protected electrically.

Cleaning

Reasons for regular and thorough cleaning (basic
cleaning):
-
Assurance of the required hygiene.
►Always keep the goods interior in a clean
condition.
-
Lowest possible energy consumption.
-
Maintenance of trouble-free operation.
-
Extension of the life of the device.
WARNING
Damage to the electrical system and
refrigerant circuit by using steam and
high-pressure cleaners. Contact with
live parts may cause electric shock.
Devices of type R-290: The refrigerant
can escape and create an explosive
gas/air mixture. Risk of fire due to
sparks or overloading.
►For basic cleaning, do not use steam
and high-pressure cleaners (→ see
Chapters 1.6.1 and 1.6.2.1).
CAUTION
Cutting injuries in the case of material
breakage.
Danger of falling.
►Do not climb onto or into the device
during cleaning.
For the safe handling of glass, see → Chapter 1.6.3.
For cleaning, wear protective gloves.

Basic cleaning

Responsibility:
Operating staff
Cleaning interval: As required (see → Chapter 10
"Checking for contamination")
Time of cleaning
Outside:
Possible at any time
Inside: When the cooling function is switched off.
Cleaning agent:
NOTE
• Material damage from excessive quantities of
cleaning agent.
►Use cleaning devices only moistened with
cleaning agent.
for at least 3 seconds. The
temperature appears on
the display screen. See →
Chapter 4.2.2.1/4.2.3.1