Installation and Operating Instructions
AIR1 RH
1500
Ambient temperature
0 - 50 °C
-20 - 50 °C
Ambient temperature with
heater terminal box
-20 - 50 °C
Outside/extract air temp .
Outside/extract air temp .
-30 - 50 °C
with electr . pre-heater
95 % RH
Humidity (max .)
ATTENTION
CHAPTER 2
INSTALLATION AND
COMMISSIONING
Central ventilation units AIR1 RH
AIR1 RH
AIR1 RH
2000
3000
0 - 50 °C
0 - 50 °C
-20 - 50 °C
-20 - 50 °C
-20 - 40 °C
-20 - 50 °C
-30 - 40 °C
-30 - 50 °C
95 % RH
95 % RH
Material damage due to the unit freezing!
The AIR1 RH units with standard equipment are intended for installation and application in frost-free rooms (room tem-
pearture > 0 °C). If the room temperature lies below 0 °C, an terminal box heater (optional) must be used to prevent
the unit freezing.
The outdoor installation of the AIR1 RH units is only permissible in combination with the matching weather protection
hood (AIR1-AAD).
The AIR1 RH units are not equipped with a condensation outlet as standard. The operating limits due to condensation
can be found using the unit selection software AIR1Select (www.AIR1Select.de).
The corrosion resistance level of the housing is C4 according to ISO 12944. The unit can be used under these condi-
tions.
Any use other than the intended use is prohibited!
2 .0

General installation instructions

2 .0 .1 Receipt

The delivery contains one of the following unit types:
AIR1 RH 1500
Ref. no. 04343
AIR1 RH 2000
Ref. no. 04344
AIR1 RH 3000
Ref. no. 04345
AIR1 RH 5000
Ref. no. 04346
AIR1 RH 6000
Ref. no. 04347
AIR1 RH 8000
Ref. no. 04348
AIR1 RH 9500
Ref. no. 04349
AIR1 RH 12000
Ref. no. 04350
AIR1 RH 15000
Ref. no. 04351
The scope of delivery also includes:
The accessories included in the scope of delivery are located on the exhaust air side of the unit (see Fig. 1).
Please check delivery immediately on receipt for accuracy and damage. If damaged, please notify the carrier immedia-
tely. In case of delayed notification, any possible claim may be void.

2 .0 .2 Storage

When storing for a prolonged time, the following steps are to be taken to avoid damaging influences:
Protection by dry, airtight and dust-proof packaging (plastic bag with desiccant and humidity indicators). The storage
place must be waterproof, vibration-free and free of temperature variations (ambient temperature limit: min. 0 °C /max.
+40 °C). Damages due to improper transportation, storage or commissioning must be verified and are not liable for
warranty.
AIR1 RH
AIR1 RH
AIR1 RH
5000
6000
8000
0 - 50 °C
0 - 50 °C
0 - 50 °C
-20 - 50 °C
-20 - 50 °C
-20 - 50 °C
-20 - 50 °C
-20 - 40 °C
-20 - 50 °C
-30 - 50 °C
-30 - 40 °C
-30 - 50 °C
95 % RH
95 % RH
95 % RH
AIR1 RH 1500/SO
AIR1 RH 2000/SO
AIR1 RH 3000/SO
AIR1 RH 5000/SO
AIR1 RH 6000/SO
AIR1 RH 8000/SO
AIR1 RH 9500/SO
AIR1 RH 12000/SO
AIR1 RH 15000/SO
Door keys and handles
Mounting brackets, gasket, M4x10 screws (size-dependent)
4
AIR1 RH
AIR1 RH
AIR1 RH
9500
12 000
15 000
0 - 50 °C
0 - 50 °C
0 - 50 °C
-20 - 50 °C
-20 - 50 °C
-20 - 50 °C
-20 - 50 °C
-20 - 40 °C
-20 - 40 °C
-30 - 50 °C
-25 - 40 °C
-25 - 40 °C
95 % RH
95 % RH
95 % RH
Ref. no. 04352
Ref. no. 04353
Ref. no. 04354
Ref. no. 04355
Ref. no. 04356
Ref. no. 04357
Ref. no. 04358
Ref. no. 04359
Ref. no. 04360
Fig .1