Press the TEST button of the diff erential switch located up-
stream from the electrical system to which the spa is connected.
If it does not trip, it may be faulty or it may have tripped due to
problems in the electrical system of the building.
Disconnect the spa and do not use it until you have identi-
fi ed and eliminated the defect.
Check the operation of the hydromassage pumps using the
"Pump"
key. The fi rst time the key is pressed the pump starts
at low speed; the second time it is pressed, high speed; the third
time, the pump turns off .
Check that the spotlights switch on and off using the key
"Light"
.
Check that the blower (if included) switches on and off using
the key "Blower"
.
Check that there are no leaks from the hydraulic connections
or other problems.
Completely disinfect the spa by carrying out "super-chlori-
nation" treatment (also called shock treatment, see chapter on
water treatment).
This operation is recommended when installing, or after a long pe-
riod of not using the spa.
After a few hours, turn off the omnipolar switch.
Open the drain valve(s) and completely empty the spa.
If included, re-install the front and side panels.
CAUTION
Do not use the spa the fi rst time you start it as there is a
high concentration of chlorine in the water during this
phase. Immediately empty the bath.
Contact the local authorities for the standards gover-
ning the discharge of chemically treated water.
Close the drain valve(s) and fi ll the spa again with fresh water
as previously explained.
Turn the omnipolar switch back on and check that the spa
works correctly.
Check and as necessary modify the water fi ltering cycles ba-
sed on how you intend to use the spa.

Installation of front and side panels

(where included)
The panels with wengé fi nished are for indoors instal-
lation ONLY.
(
2, part.1) Insert the rubber spacers on the threaded pins
(located on the lower part of the support legs).
(
2, part.2) Set one of the two panels with corners (A-B) at
the edge of the tub and check that the slots on the lower bracket
coincide with the threaded pins.
(
2, part.3-4) Insert the edge of the upper bracket in the
under-edge profi le. Then set the panel next to the tub, so that
the threaded pins are inserted into the slots. (part.5)Temporarily
fasten the panel with the indicated nuts.
Install the other panel in the same way.
Using the same procedure, install the front panels (C and D). To
make insertion easier, if necessary pull out on panels A and B.
Finally, make sure the panels are aligned with one another.
Permanently secure the panels by tightening the nuts all the
way, until any vertical gaps are closed between the panel and
the corner.
- Customizable panels (where included)
These are panels upon which coverings with a thickness of a few
millimetres can be applied (leather, fabric, etc.).
If you want to apply thicker coverings (mosaic, tiles, etc.), you
can partially mill the unfi nished panel (which has a thickness of
about 15 mm) so that the covering is aligned with the corners.
In any case, to prevent accidental damage during application
of the covering, you should remove the corners, as shown (
2, part.6).

Control panel and functions

(
4) All spa functions are managed by the control panel on the
tub, as are the respective settings/programming.

Setting the water temperature

The water is heated by a tubular electrical heater. Do not set an
excessively high water temperature, i.e. over the limit of 40 °C. The
recommended temperature is 35-36 °C.
NOTE: If the electric consumption limiter is activated (se the related
chapter) should the pump be turned on at high speed, the heater
will be turned off (the LED for the symbol
splay) and it is turned back on, if needed, 5 minutes after the pump
is turned off .
Temperature unit of measure
The temperature scale is set to °C (Celsius). It can be changed to
°F (Fahrenheit) as follows:
Press and hold the key "Light"
you see the message "cFn" (if necessary use the key "Up/Down"
to scroll the menu until you come to "cFn").
Press the key "Light"
32
32
will fl ash on the di-
for about 12 seconds until
again to confi rm.