Bosch HTD 6 serie Serviceanleitung Seite 71

Scheinwerfereinstellgeräte
Vorschau ausblenden Andere Handbücher für HTD 6 serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Touch cal.
i
The touch screen is calibrated here:
1. Select "TOUCH CAL." in the" SERVICE" screen .
2. The calibration is performed using three selected
points; each point must be selected three times.
3. The "SERVICE" screen appears following calibration.
Robert Bosch GmbH
Service setting – HTD 8xx | HTD 6xx / HTD 8xx | 71
Test date
i
The date for the next test (calibration) is set here:
1. Select "TEST DATE" in the "SERVICE" screen.
2. Enter the date for the next test.
3. Confirm with the "OK" key.
4. Press the
Preview
i
The light pattern panel can be viewed and zero point
calibration performed here:
1. Select "PREVIEW" in the "SERVICE" screen.
2. The "SERVICE" screen is displayed by pressing twice
on the screen.
key to access the "SERVICE" screen.
1 692 106 011
en
|
2019-03-26