Herunterladen Inhalt Inhalt Diese Seite drucken

Bosch HTD 6 serie Serviceanleitung Seite 70

Scheinwerfereinstellgeräte
Vorschau ausblenden Andere Handbücher für HTD 6 serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

en
70 | HTD 6xx / HTD 8xx | Service setting – HTD 8xx
Tolerances
i
The tolerances to be used for headlamp assessment
are specified here.
1. Select "TOLERANCES" in the "SERVICE" screen.
2. The
key is used to select the test standards for
which the tolerances are to be set.
$
ECE
$
SAE
$
VOR
$
VOL
3. The
key is used to select the headlamps for
which the tolerances are to be set.
$
- Low beam
$
- High beam
$
- Fog lamps
4. Set the tolerances:
$
T.O.D.:
Tolerance, right
$
T.O.S.:
Tolerance, left
$
T.V.U.:
Tolerance, up
$
T.V.D.:
Tolerance, down
$
L.MAX:
Maximum intensity value
$
L.min:
Minimum intensity value
$
D.L.:
Tolerance for difference in % between
right and left headlamp
intensity
5. Confirm with the
6. The
key resets the settings.
7. Press the
key to access the "SERVICE" screen.
Calibration
See section „4.6 Luminous intensity – HTD 8xx"
|
1 692 106 011
2019-03-26
key.
Unit
i
The unit for the measured values to be used for
headlamp assessment is specified here:
1. Select "UNIT" in the "SERVICE" screen.
2. The
key is used to select the test standards for
which the unit is to be set.
$
ECE
$
SAE
$
VOR
$
VOL
3. The
key is used to select the headlamps for
which the unit is to be set.
$
- Low beam
$
- High beam
$
- Fog lamps
4. Set the desired unit.
5. Confirm with the
6. The
key resets the settings.
7.
Press the
key to access the "SERVICE" screen.
key.