Technical Data

Voltage
Type
Power input
Blade diameter
Blade bore
Max. kerf thickness
Max. blade thickness
Blade speed
Max. crosscut capacity at 90/90°
Max. mitre cut capacity at 45˚
Max. depth of cut 90˚
Max. depth of bevel cross-cut 45˚
Mitre (max. positions)
Bevel (max. positions)
0° mitre
Resulting width at max. height 70 mm
Resulting height at max. width 300 mm
45° mitre left
Resulting width at max. height 70 mm
Resulting height at max. width 212 mm
45° mitre right
Resulting width at max. height 70 mm
Resulting height at max. width 212 mm
45° bevel left
Resulting width at max. height 50 mm
Resulting height at max. width 300 mm
31.62° mitre, 33.85° bevel
Resulting height at max. width 254 mm
Blade stopping time
Weight
Noise values and/or vibration values (triax vector sum) according to EN62841:
L
(emission sound pressure level)
PA
L
(sound power level)
WA
K (uncertainty for the given sound level)
The vibration and/or noise emission level given in this information sheet has been measured in
accordance with a standardised test given in EN62841 and may be used to compare one tool
with another. It may be used for a preliminary assessment of exposure.

WARNING: The declared vibration and/or noise emission level represents the main
applications of the tool. However if the tool is used for different applications, with different
accessories or poorly maintained, the vibration and/or noise emission may differ. This may
significantly increase the exposure level over the total working period.
An estimation of the level of exposure to vibration and/or noise should also take
into account the times when the tool is switched off or when it is running but not
actually doing the job. This may significantly reduce the exposure level over the total
working period.
Identify additional safety measures to protect the operator from the effects of vibration
and/or noise such as: maintain the tool and the accessories, keep the hands warm
(relevant for vibration), organisation of work patterns.
24
DW712
DW712N
V
230
230
AC
7
5
W
1600
1600
mm
216
216
mm
30
30
mm
2.6
2.6
mm
1.8
1.8
min
-1
3500–4600
5400
mm
300 x 70
300 x 70
mm
212
212
mm
70
70
mm
50
50
left
50˚
50˚
right
60˚
60˚
left
48˚
48˚
right
mm
300
300
mm
70
70
mm
212
212
mm
70
70
mm
212
212
mm
70
70
mm
300
300
mm
50
50
65
65
s
<10
<10
kg
21
21
dB(A)
92
92
dB(A)
105
105
dB(A)
3
3
EC-Declaration of Conformity
Machinery Directive
Mitre Saw
DW712, DW712N
D
WALT declares that these products described under Technical Data are in compliance with:
e
2006/42/EC, EN62841-1:2015 +AC:2015; EN62841-3-9:2015 + AC:2016 + A11:2017.
These products also comply with Directive 2014/30/EU and 2011/65/EU. For more information,
please contact D
WALT at the following address or refer to the back of the manual.
e
The undersigned is responsible for compilation of the technical file and makes this declaration
on behalf of D
WALT.
e
Markus Rompel
Vice President of Engineering, PTE-Europe
D
WALT, Richard-Klinger-Straße 11,
e
D-65510, Idstein, Germany
19.07.2019
WARNING: To reduce the risk of injury, read the instruction manual.
Definitions: Safety Guidelines
The definitions below describe the level of severity for each signal word. Please read the
manual and pay attention to these symbols.

DANGER: Indicates an imminently hazardous situation which, if not avoided, will result
in death or serious injury.

WARNING: Indicates a potentially hazardous situation which, if not avoided, could result
in death or serious injury.

CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result
in minor or moderate injury.
NOTICE: Indicates a practice not related to personal injury which, if not avoided, may
result in property damage.

Denotes risk of electric shock.

Denotes risk of fire.
General Power Tool Safety Warnings

WARNING: Read all safety warnings, instructions, illustrations and specifications
provided with this power tool. Failure to follow all instructions listed below may result
in electric shock, fire and/or serious injury.
SAVE ALL WARNINGS AND INSTRUCTIONS
FOR FUTURE REFERENCE.
The term "power tool" in the warnings refers to your mains-operated (corded) power tool or
battery-operated (cordless) power tool.
1) Work Area Safety
a ) Keep work area clean and well lit. Cluttered or dark areas invite accidents.
b ) Do not operate power tools in explosive atmospheres, such as in the presence of
flammable liquids, gases or dust. Power tools create sparks which may ignite the dust
or fumes.
c ) Keep children and bystanders away while operating a power tool. Distractions can
cause you to lose control.
2) Electrical Safety
a ) Power tool plugs must match the outlet. Never modify the plug in any way. Do
not use any adapter plugs with earthed (grounded) power tools. Unmodified plugs
and matching outlets will reduce risk of electric shock.
b ) Avoid body contact with earthed or grounded surfaces such as pipes, radiators,
ranges and refrigerators. There is an increased risk of electric shock if your body is
earthed or grounded.
c ) Do not expose power tools to rain or wet conditions. Water entering a power tool
will increase the risk of electric shock.
d ) Do not abuse the cord. Never use the cord for carrying, pulling or unplugging
the power tool. Keep cord away from heat, oil, sharp edges or moving parts.
Damaged or entangled cords increase the risk of electric shock.
e ) When operating a power tool outdoors, use an extension cord suitable for
outdoor use. Use of a cord suitable for outdoor use reduces the risk of electric shock.
f ) If operating a power tool in a damp location is unavoidable, use a residual
current device (RCD) protected supply. Use of an RCD reduces the risk of electric shock.